Page 1
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
DELUXE
WATTS 25
ULTRA 5
RO-TFM-4SV
RO-TFM-5SV
PUR-TEK
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier, Inc. 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381
Phone: 800-752-5582 www.wattspremier.com Fax: 623-866-5666
Save manual for future reference
MODELS
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the product’s failure.
System tested and certied by NSF International against NSF/
ANSI Standard 58 for the reduction of the claims specied on the
performance data sheet.
Manual Edition: 01/19/12
P/N 199348
EPA / ETV Test veried performance.
Physical removal of microbial
contamination agents in drinking water.
Seitenansicht 0
1 2 3 4 5 6 ... 28 29

Inhaltsverzeichnis

Seite 1 - P/N 199348

Page 1 INSTALLATION, OPERATION AND MAINTENANCE MANUALDELUXEWATTS 25ULTRA 5RO-TFM-4SVRO-TFM-5SVPUR-TEKRefer to enclosed warranty for ope

Seite 2

Page 10 Turn off the cold water supply to the faucet by turning the angle stop valve completely off. Open cold water sink faucet to rel

Seite 3 - Table of Contents

Page 11 Drain Saddle ts standard 1 ¼” – 1 ½” drain pipesDrain Saddle InstallationStep 9Step 10Step 11The drain saddle must be mounted

Seite 4 - INSTALLATION & STARTUP

Page 12 Reverse Osmosis Module MountingStep 16 Determine best location for the RO module to be mounted to allow for future system main

Seite 5 - Item # Part # Description

Page 13 Blue Tube Connection (From System)Position the RO storage tank in a desired location. You may stand it upright or lay it on it

Seite 6 - Marble Counter-top

Page 14 Remove the seal caps from both ends of the nal lter. Cut the blue tubing between the RO faucet and the storage tank at a des

Seite 7 - Parts List

Page 15 Register by phone, fax, mail or internet. Watts Premier uses this information only to provide you with a lter change reminde

Seite 8 - CAUTION!

Page 16 6 Month System MaintenanceStep 1 Step 3Let system sit for one minute after the tank is empty to let the system depressurize

Seite 9

Page 17 Annual MaintenanceStep 1√ Stage 1 - Sediment Filter (part #: 104017) √ Stage 2 & 3 - Carbon Block Filter (part #: 101009-Wh

Seite 10 - Adapt-a-Valve Installation

Page 18 Membrane ReplacementUse a 5/8” wrench to remove the Green Tube tting on the left side of the horizontal membrane housing (end

Seite 11 - Drain Saddle Installation

Page 19 Once all water in the tank is purged, check air pressure using an air pressure gauge, it should read between 5 - 7 PSI. (Digita

Seite 12 - Tank Tee Installation

Page 2 Thank you for your purchase of a state of the art Watts Premier Reverse Osmosis (RO) water treatment system. Water quality conce

Seite 13

Page 20 TROUBLE SHOOTINGProblem Cause Solution1. Low/Slow Production Low Water Pressure Assure a minimum of 40 psi incoming

Seite 14 - Final Filter Installation

Page 21 RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:Note: Depending on incoming feed water conditions replacement time frame ma

Seite 15 - Congratulations!

Page 22 California CerticationState of CaliforniaDepartment of Health ServicesWater Treatment DeviceCertificate Number1452Date Issued:

Seite 16 - 6 Month System Maintenance

Page 23 Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It

Seite 17 - Annual Maintenance

Page 24 50 GPD Membrane Compatible with Watts Premier Reverse Osmosis systems, this 50 GPD membrane generates a greater amount of water

Seite 18 - Membrane Replacement

Page 25 Removing chlorine from your showerDeluxe Shower Handle with Built in Filter Replacement lters 2PK5-Way Massaging S

Seite 19

Page 26 4 Ways to Register1. On-line at www.wattspremier.com2. Call in your information 1-800-752-55823. Fax in your information 6

Seite 20 - TROUBLE SHOOTING

Page 27 WARRANTY REGISTRATIONPlease Fill out and keep for your RecordsInsert into envelope and return to Watts PremierFirst Name:_____

Seite 21 - Peoria, AZ 85381

Page 28 Service RecordDate of Purchase:__________ Date of Install:___________ Installed by:__________________NOTES: Date1st

Seite 22 - California Certication

Page 29 Limited WarrantyWhat your Warranty Covers:If any part of your WATTS PREMIER Reverse Osmosis System is defective in workmanship

Seite 23 - Arsenic Fact Sheet

Page 3 Table of Contents Operational Parameters ...

Seite 24

Page 4 Installation must comply with State and local plumbing regulations. Do not use with water that is micro biologically unsa

Seite 25

Page 5 Item # Part # Description17 131012 SLEEVE-PLASTIC-1/4”18 131017 INSERT-BRASS-1/4”19 131021 HEX NIPPLE-BRASS-1/420

Seite 26 - WARRANTY REGISTRATION

Page 6 After drilling, remove all sharp edges and make sure the surroundings of the sink are cooled before mounting the faucet.Step 3S

Seite 27

Page 7 Feed both the red and black tubing through the pre drilled hole in the sink/counter until faucet is seated.Under the sink - on t

Seite 28 - Service Record

Page 8 WATTS Premier Monitored (Top Mount) Faucet Installation123ba44. Feed the toggle bolt and tubes through the mounting hole in The

Seite 29 - Limited Warranty

Page 9 Helpful Installation Tips for the Watts Top Mount FaucetDuring shipping/handling the tog-gle bolt on your new faucet may push up