Premier RO-TFM-5SV Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Wasserspender Premier RO-TFM-5SV herunter. Premier RO-TFM-5SV Product data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Page 1
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier, Inc. 1725 W. Williams Drive C-20 Phoenix, AZ 85027
Phone: 800-752-5582 www.wattspremier.com Fax: 623-931-0191
Save manual for future reference
MODEL
WP-5
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the products failure and possible damage to property.
System Tested and certified by NSF International against ANSI/NSF
Standard 58 for the reduction of claims specified on performance data sheet.
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1

Page 1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.

Seite 2

Page 10 3/8” Black Tube Connection Measure the black tube from faucet to the black drain saddle and make a straight cut with a sharp knife though tub

Seite 3 - Table of Contents

Page 11 Thread the larger (3/8”) white plastic connector into the other end of the final filter. Step 29 Thread the smaller (1/4”) white plastic conn

Seite 4 - Operational Parameters

Page 12 Start up Instructions Register warranty by mail, phone, or internet. Watts Premier uses this information only to provide a filter change rem

Seite 5

Page 13 √ One 10” sediment filter (part no. 104017) √ Bucket to catch water from filter housings. √ Two 10” carbon filters (part no. 101009) Clean al

Seite 6 - Faucet Installation

Page 14 Annual Maintenance Perform 6 month system maintenance. (previous section) The Final Filter (should be replaced annually. Remove white nuts a

Seite 7 - Adapta Valve Installation

Page 15 Pull firmly on the membrane to remove from the housing and discard. Unwrap new membrane and lubricate the o-rings with water soluble lubricati

Seite 8 - Tank Elbow Installation

Page 16 Check air pressure when tank is empty. Checking Air Pressure in the Tank Use a digital air gauge to check the air pressure in the tank. You s

Seite 9 - Green Tube Connection

Page 17 TROUBLE SHOOTING MELBORPESUACSNOITULOSnoitcudorPwolS/woL.1erusserPretaWwoL .erusserpretawgnimocniisp04fomuminimaerussAsierusserpretawemohfipmu

Seite 10 - 3/8” Black Tube Connection

Page 18 Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measur

Seite 11 - Final Filter Installation

Page 19 California Certification

Seite 12 - Start up Instructions

Page 2 Thank you for your purchase of a state of the art Watts Premier Reverse Osmosis (RO) water treatment system. Water quality concerns are quickly

Seite 13 - 6 Month System Maintenance

Page 20 RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS: Note: Depending on incoming feed water conditions replacement time frame may vary. Descri

Seite 14 - Membrane Maintenance

Page 21 W a tts Part Num ber Description100014 10" In Line Filter101009 Filter, Carbonblock 5m ic104017 Filter, SED-SPUN-10" CTG (5M -10)110

Seite 15 - Page 15

Page 22 Watts Premier has other fine water filtration products and accessories to enhance your water and to compliment your existing RO System. Lis

Seite 16 - Page 16

Page 23 Wave Faucets by Watts Premier allow for a variety of choices to match your kitchen decor. Available colors include: Part No. 116022 Chrome

Seite 17 - TROUBLE SHOOTING

Page 24 Removing chlorine from your shower Deluxe Shower Handle with Built in Filter Replacement filters 2PK 5-Way Massaging Spray 72" Rein

Seite 18 - Page 18

Page 25 4 Ways to Register 1. Online at www.wattspremier.com 2. Call in your information 1-800-752-5582 3. Fax in your information 623-931-0191 F

Seite 19 - California Certification

Page 26 WARRANTY REGISTRATION Please Fill out and keep for your Records Insert into envalope and return to Watts Premier First Name:_________________

Seite 20 - Performance Data Sheet

Page 27 Service Record Date of Purchase:__________ Date of Install:___________ Installed by:__________________ NOTES: ________________________________

Seite 21 - Page 21

Page 28 Limited Warranty What your Warranty Covers: If any part of your WATTS PREMIER Reverse Osmosis System is defective in workmanship (excluding re

Seite 22 - Page 22

Page 3 With proper installation and maintenance, this system will provide you with high quality water for years to come. All of Watts Premier's

Seite 23 - Page 23

Page 4 Hardness: Recommended hardness should not exceed 10 grains per gallon, or 170 ppm. System will operate with hardness over 10 grains but t

Seite 24 - Page 24

Page 5 Note: Make sure the surroundings of the sink are cooled before mounting the faucet to the sink after drilling. Remove all sharp edges. Step

Seite 25 - WARRANTY REGISTRATION

Page 6 • Faucet assembly • Black Shank Nut • Slotted washer • Gasket • 3' Blue Tube Faucet Installation Remove black shank nut and insert

Seite 26

Page 7 Adapta Valve Installation Turn off cold water supply to the kitchen faucet by turning the angle stop valve clockwise. Reverse Osmosis Module Mo

Seite 27 - Service Record

Page 8 Drain Saddle fits standard 1 ¼” – 1 ½” drain pipes Drain Saddle Installation Step 14 Step 15 Step 16 Thread the plastic elbow (supplied in the

Seite 28 - Page 28

Page 9 Green Tube Connection Measure the green tube coming from the port marked TAP on the Reverse Osmosis Module over to the adapta valve attached t

Kommentare zu diesen Handbüchern

Keine Kommentare